kobalttools.com
CARE AND MAINTENANCE
All maintenance should only be carried out by a qualied technician.
Cleaning
Before cleaning or performing any maintenance, remove the battery pack from the drill/driver. For
safe and proper operation, always keep the tool and its ventilation slots clean.
Always use only a soft, dry cloth to clean your drill/driver. Never use detergent or alcohol.
14. Chuck Removal
The keyless chuck (A) can be removed and replaced.
a. Lock the trigger switch by placing the direction-of-
rotation selector (E) in the center position.
b. Open the chuck jaws.
c. Use a screwdriver (not included) to remove the
chuck screw by turning it in a clockwise direction.
d. Insert a 5/16-in. or larger hex key (not included) into
the chuck of the drill/driver and securely tighten the
chuck jaws around the hex key.
e. Tap the hex key sharply with a mallet (not included)
in a counterclockwise direction. This will loosen the
chuck for easy removal.
NOTICE: The chuck screw has left-handed threads.
Attach a new chuck to the spindle and tighten the chuck
screw.
TROUBLESHOOTING
WARNING
Place the direction-of-rotation selector (E) in the center lock position and detach the battery pack
from the drill/driver before performing troubleshooting procedures.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The drill/driver does not
work.
Battery pack is depleted. Charge the battery pack.
Bit cannot be installed. Chuck is not released. Release the chuck.
Bit does not t the chuck. Use an appropriate bit or use
a suitable adaptor.
Motor overheating. Cooling vents are obstructed. Clean and clear vents. Do not
cover vents with hand during
operation.
The LED worklight blinks
rapidly.
The tool has stopped working to
protect internal circuits.
Release the trigger switch,
wait for the tool to cool down,
then and start the tool again.
The LED worklight blinks
slowly.
The battery charge is very low. Charge the battery.