TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Pump does not prime. 1. Prime spray valve is set to
spray position.
2. Sprayer is turned off.
3. Prime tube is clogged.
4. Suction tube is not submerged.
5. Inlet screen on suction tube is
clogged.
1. Set prime spray valve to prime
position.
2. Turn sprayer on.
3. Unclog prime tube.
4. Submerge suction tube.
5. Check and clear any clogs in inlet
screen.
Sprayer is functioning
and spraying, but
spray pressure drops
while in use.
1. Material being sprayed is
running low.
2. Single seal tip is worn and
needs to be cleaned or
replaced.
3. Spray gun housing may be
clogged.
4.
clogged or not inserted
properly.
5. Material being sprayed may
be too thick.
6. Suction tube is not connected
properly.
7. Suction tube may be
damaged.
1. Add or replace material being
sprayed.
2. Turn off machine. Remove and
inspect single seal tip. Clean and/or
replace.
3. Clean spray gun housing. Flush
spray gun housing clear of any
debris.
4. Turn off machine. Remove internal
properly and not clogged.
5. Check material data sheet from
material supplier to make sure single
seal tip size is compatible.
6. Check suction tube. Reconnect if
loose.
7. Check suction tube. Replace if
damaged.
Prime spray valve is
set, but does not allow
1. Prime spray valve is damaged
or connection to prime spray
valve is damaged.
1. Contact local paint repair store or
local retailer for suitable replacement
components.
Spray gun housing
leaks.
1. Incorrect connection with high
parts are worn.
1. Check connection with high pressure
contact local paint repair store or
local retailer for suitable replacement
components.
Single seal tip and tip
housing leak.
1. Incorrectly tightened or
threaded, or worn single seal
tip.
1. Check connection to make sure
connection is not misthreaded.
Replace if single seal tip is worn.
Paint pattern is uneven. 1. Pressure is not set correctly.
2. The inlet screen on the
suction tube may be clogged.
3. Suction tube connection is
loose.
4. Material being spraye
d is too
thick for single seal tip size.
5.
Single seal tip is worn and
needs to be cleaned or replaced.
1. Adjust pressure on machine so
pattern is even/consistant.
2. Unclog inlet screen.
3. Make sure suction tube is properly
connected.
4. Check material data sheet to make
sure single seal tip is compatible.
5. Clean or replace single seal tip.