TP-7044 6/23 55
Engine Cooldown (Delay) Active. This notice message indicates that the delay for engine cooldown is active where the
generator set will continue to run after the OFF/RESET button is pressed. The unit will continue to run until the time delay times
out.
Engine Start Aid Active. This notice message indicates that the start aid is active and will energize an engine equipped preheat
or ether system during the crank cycle. Use SiteTechâ„¢ software to set up this feature.
Engine Started. This status indicates that the generator set start circuit is closed allowing the engine to crank and run.
Engine Stopped. This status indicates that the generator set start circuit is open causing the engine to shut down.
Generator Running. This notice indicates that the generator set has started and is running.
Load Priority # Shed. This status message indicates the digital output for load priority # (1, 2, 3, 4, 5, or 6) shed is active
(contacts closed), indicating the 1st, 2nd, 3rd, 4th, 5th, or 6th priority load shed has been activated.
Remote Start. This notice indicates that the generator set start circuit was closed from a remote location allowing the engine to
crank and run. The remote location is typically a set of contacts on a transfer switch or remote start switch.
Remove Breaker Trip. This notice message indicates that the controller considers the breaker to be safe to close. The breaker
may be closed or preparing to close when this notice is displayed. This notice only appears in paralleling applications (where
the bus sensing is connected to the bus side of the paralleling breaker).
Run Button Acknowledged. This notice message indicates that the RUN button on the controller has been pushed.
System Ready. This status indicates that the generator set is in the AUTO mode and available to start if the start circuit is
closed.
2.14.6 Controller Resetting (Following System Shutdown or Warning)
Use the following procedure to restart the generator set after a system shutdown or to clear a warning lamp condition.
This procedure includes the resetting of the optional remote annunciator.
Refer to the Emergency Stop section, to reset the generator set after an emergency stop.
1. Disconnect the generator set load using the line circuit breaker or automatic transfer switch.
2. Correct the cause of the fault shutdown or warning. See the Safety Precautions and Instructions section of this manual
before proceeding.
Note:
Always identify and correct the cause of a fault shutdown before resetting the controller.
3. Reset the fault by pressing the OFF/RESET button.
4. Start the generator set by pressing the generator set OFF/RESET button and then press the RUN button.
When equipped, the remote annunciator alarm horn sounds. Press the ALARM SILENCE/LAMP TEST button to stop
the alarm horn. The alarm silenced lamp turns on if the alarm is silenced.
5. Test operate the generator set to verify correction of the shutdown cause by pressing the RUN button.
6. Press the generator set OFF/RESET button to stop the generator set.
7. Press the generator set AUTO button.
8. Silence the controller alarm horn by pressing the ALARM SILENCE button.
9. Reconnect the generator set load via the line circuit breaker or automatic transfer switch.
10. When equipped, the remote annunciator alarm horn sounds. Press the ALARM SILENCE/LAMP TEST button to stop
the alarm horn. The alarm silenced lamp turns on if the alarm is silenced.

Table of Contents

Other manuals for Kohler 12EFKOZD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 12EFKOZD and is the answer not in the manual?

Kohler 12EFKOZD Specifications

General IconGeneral
BrandKohler
Model12EFKOZD
CategoryPortable Generator
LanguageEnglish

Related product manuals