1070157-T01-E
TROUBLESHOOTING
No flushing
(Indicator not flashing).
1. No power or mistake connected.
2. There is an object within the sensing distance.
3. The sensing window needs cleaning.
1. Check the power connect.
2. Remove the object .
3. Clean the window.
Keep flushing indicator not
flashing.
Battery indicating light
keeps flashing and no
flushing.
1. The small hole of valve core is blocked.
2. The filter of valve core is blocked.
Out of electricity.
(Only for 16320T-M/16321T-M)
1. Clean the small hole of valve core with
thin steel wire.
2. Wash the filter of valve core with a brush.
Replace batteries.
Please make following checks before repair:
Symptoms
Probable causes
Corrective actions
If the trouble remains after above-mentioned actions are taken, please contact with us via distributor.
()
1.
2.
3.
1.
2.
3.
1.
2.
( 16320T-M/ )16321T-M
1.
2.
No flushing or poor
flushing while the indicator
can flash.
1. Still in the waiting status.
2. Adjusting bolt not fully open
3. Low water pressure.
4. Filter is obstructed.
5. The connector is not connected well.
1. Wait for 10 minutes.
2. Open the adjusting bolt.
3. Improve water supply.
4. Clean the filter.
5. Check the connector.
1.
2.
3.
4.
5.
1. 10
2.
3.
4.
5.
-13-