8
TP-7213 7/21
Section 6. Transporting and Storing the Generator Set
6.1 Transport and Handling Conditions
The unit should be handled gently and sudden movements should be avoided. Ensure that the place where it is to be stored or
used is carefully prepared beforehand. Before any fixed installation on a trailer or inside a vehicle, consult one of our approved
dealers.
Before transporting the unit, take the following necessary precautions:
1. Check that the routes to be used are smooth and drivable. If it proves necessary to use uneven roads, drain the fuel into a
container before setting off.
2. Check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the battery (if fitted).
3. The unit should always be transported in its normal operating position; never lay it on its side. Ensure that the unit cannot
fall from the vehicle carrying it, but without exerting too much force (risk of damaging the unit).
6.2 Storage Conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest dealer or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
Drain the fuel and change the engine oil:
1. Start the unit and allow it to operate until it runs out of fuel.l
2. Set the engine on/off switch to OFF (A7).
3. Clean the fuel filter (A12) and the sediment bowl (A13-C3).
4. Close the fuel valve (A5).
5. Top up the oil.
Grease the cylinder and valves:
6. Remove the spark plug (A15-E2) (
see the section "Replace the spark plug"
) then, via its aperture, pour in approximately
one teaspoon of new engine oil.
7. Refit a new spark plug in its place.
8. Pull the starter-recoil reel handle (A9) several times to distribute the oil inside the cylinder.
Storing the unit:
9. Clean the unit.
10. Cover it with a protective cover and store it in its normal position, in a clean, dry and well ventilated area.
Section 7. Troubleshooting
Problem
Possible Causes
Engine Not
Starting/
Running
Abnormally
Engine
Stopped
No Electric
Current
Tripping of
Circuit
Breaker
Load connected to generator set during start-up
Start and Stop control ON or OFF
Oil level too low
Unsuitable fuel
Fuel level too low
Fuel valve closed
Clogged fuel filter
Clogged fuel strainer
Clogged air filter
Faulty spark plug
Fuel supply blocked or leaking
Faulty starter battery
Blocked ventilation inlets
Circuit protectors not actuated
Faulty appliance supply cord
Faulty electrical sockets
Faulty alternator
Device connected or faulty cord
Overload
Battery incorrectly connected