Cabin Sealing Efficiency Test Procedure
Start Engine – Pressuriser System is ON
Ensure all windows & door(s) are CLOSED correctly (no cabin pressure leaks)
NOTE: for a new cabin with effective seals, you may need to open a window slightly before closing the door to bleed the static cabin air pressure outwards. Once door is fully
closed then close windows to begin testing.
Enter the Settings menu via the touch screen button.
Select and press the System Check button to go to System Test – Max Fan.
Record / photograph the maximum cabin pressure achieved.
CABIN SEALING TEST PROCEDURE
Press “System Check – Set
Max” box.
Record / Photograph the cabin
pressure result (Max Fan Speed).
12:18 12/04/2022 100%
System Test – Max Fan
Cabin Pressure
425 Pascals
12:18 12/04/2022 25%
Cabin Pressure 50 Pa