EasyManuals Logo
Home>Komatsu>Compact Loader>WA270-8

Komatsu WA270-8 Service Manual

Komatsu WA270-8
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #348 background imageLoading...
Page #348 background image
Check point Check items
Maintenance schedule
Check before op-
eration
6 months inspec-
tion
Replacement in-
terval
Belt Looseness, damage Implement - 2 years
Refrigerant gas Charge amount - Implement -
Piping
Looseness, damage, leak-
age
- Implement -
Receiver drier - - - 2 years
METHOD FOR REPLACING SLOW-BLOW FUSE
NOTICE
• When replacing the slow-blow fuse, be sure to turn the starting switch to OFF position and, after
confirming that the system operating lamp is not lit, set the battery disconnect switch key to OFF
position.
• Replace the slow blow fuse with the one of the same capacity.
Should the slow-blow fuse is blown, investigate the cause and take necessary actions.
The slow-blow fuse is on the side of the engine on the left side of the machine.
1.
Remove the cover (1).
2.
Open the cover (2) of the slow-blow fuse box and check it.
3.
Turn the starting switch to OFF position (A).
4.
Turn the battery disconnect switch key to OFF position.
Check that the system operating lamp is not lit.
5.
Remove the slow-blow fuse box from the machine body.
MAINTENANCE PROCEDURE MAINTENANCE