6 OPERATION
Thispartdescribesthefunctionsandproceduresforoperatingtheprinter.
CAUTION:
Failuretoobservetherequisiteheatinguptimeofminimum15minutesleadstoirriversable
damagetothetextcharacters/clichés,thehotrollandthecodingunit.
6.1 Powering up
1. Checkbyvisualinspectionfordamageoftheprinter.
2. Checkifalloftherelevantcablesareconnected.
3. Settheairpressureto0.4MPa,withtheairregulatoronthesideofthecontrolbox.
4. Switchthecontrolboxon.Theprogrambootswhiletheprintertypeisdisplayed.
Fig. 6.1 FirmwareforPrintertypemessage.
5. After3secondstheStopmodemenuappears.
Fig. 6.2 STOPMODEmenu.
6. Makesureahotrollisplacedintheheatingring,refertosection 5.5.2.Placingatextholder.
7. Makesureatextholderisplaceintheprinthead,
refertosection 5.5.3Placingahotroll.
8. Waitatleast15minutestoheatupthehotrollandprinthead.
9. Proceedwithstep14,iftheparametersdoesnothavetochange.
10. PresstheRIGHTARROWtobrowsethroughtheparametersandalterthedesiredparameter.Referto
section
6.3,’Parameter/messagescreens’and AppendixF,‘Quickreference’.Whensettingupthe
printersetthetemperatureto135°Ctostartwith.
Theparameterbrowsesequenceis:
PRESET,SETDELAY,SETTEMP,SETTIME,
FIRMWAREmessage,SETLCDCONTRAST,SETALARM,EXT.BUSY,READYTEMP,POWERON.
11. Pressthe
STOPkeytoreturntotheSTOPMODEmenu.
12. PresstheTESTkeytomakeatestprint.
13. ChecktheprintqualityandchangetheSETTIMEand/orSETTEMPparameterifnecessary(step10).
Note:
Theprintpressureisalsoimportantfortheprintquality.
Note:
Iftheprintdoes
notresultinacompletelyevenimage,thepositionofthecodingunitprobably
needstobere‐adjusted.
14. PresstheSTARTkeytoentertheRUNMODEmenu.
i
i