3. CALIBRATION
1) In operation screen, when you press key, below screen will display.
1-1) Integrated Zero Adjustment
☞ It will start when belt is on
No-load state.
① Start belt in No-load state.
② When the belt operated at a steady rate,
press key , and Integrated Zero
adjustment start.
③ When it arrives a standard pulse, Controller
stop calculating automatically.
④ If you press the key after
calculating, integrated Zero value is inputted.
⑤ After doing once more ①~③ ,
when Integrated Zero value is in scope
of ±0.12%,
adjustment is finished.
☞ press key to go former screen.
3/5