ENGLISH
8
PREPARATION FOR FIRST OPERATION
쎱 Coolant
3
CAUTION:
To avoid personal injury:
¡ DO NOT remove the radiator
cap while coolant is hot. When
cool, rotate the radiator cap to
the first stop to allow excess
pressure to escape. Then
remove cap completely.
¡ Place the machine on a level
surface.
¡ Keep the machine at least 1m
away from any structures to
provide ample space for the
cooling air inlet and outlet.
To add coolant to the radiator, remove the radiator
top cover and remove the radiator pressure cap. Add
coolant until the water covers the radiator core tubes.
Next, open the door of machine on the right side and
add coolant to the specified level (punched line) of the
reserve tank. Thereafter, add water only to the reserve
tank.
Always use antifreeze and anti-boil to prevent cooling
system damage from freezing or overheating.
Pre-mix antifreeze before adding to the radiator.
Use permanent type 50/50 mix anti-freeze.
Do not intermix different brands.
(1) Radiator top cover
(2) Radiator cap
(3) Coolant filling port
Coolant capacity liters.
Including the reserve tank
쎱 Engine Oil
The generator has been shipped without engine oil.
Fill with oil or it will not start.
1. Place the machine on a level surface.
2. Remove the oil cap.
3. Add engine oil of grade CD or higher, up to the
upper mark on the oil dipstick.
(1) Engine oil cap
(2) Oil dipstick
Engine oil capacity liters.
Model Capacity
KJ-T130DX, KJ-T160DX,
KJ-T130DX-AUS
5.6
KJ-S130VX, KJ-S150VX,
KJ-T180VX, KJ-T210VX,
KJ-S130VX-AUS, KJ-T180VX-AUS
7.6
KJ-T300, KJ-S240-AUS, KJ-T300-AUS
13.2
(1) Oil dipstick (A) PROPER OIL LEVEL
(B) Upper level
(C) Lower level