ENGLISH
18
OPERATING THE ENGINE
Single phase 3 terminal type
¡) KJ-S130VX
50Hz 110V Use U-N
V-N
50Hz 220V Use U-V
™) KJ-S150VX
60Hz 110V Use U-N
V-N
60Hz 220V, 240V Use U-V
(1) Light (4) Electric Drill
(2) Television (5) Motor Pump
(3) Air conditioner
3 phase and single phase 4 terminals type
¡¡
¡¡
¡ For 3 phase power source
¡) KJ-T130DX, KJ-T180VX, KJ-T300
50Hz,380,415V Use W-V-U
¤) KJ-T160DX, KJ-T210VX
60Hz 220,380V Use W-V-U
(1) Motor
¡ For single phase Power Source:
¡) KJ-T130DX, KJ-T180VX, KJ-T300 Use O-U
50Hz 220,240V O-V
O-W
¤) KJ-T160DX, KJ-T210VX Use O-U
60Hz 127,220V O-V
O-W
(1) Light
(2) Television
(3) Air conditioner
¡ Connecting 3 phase Power Source to
Single Phase Load.
¡) KJ-T130DX, KJ-T180VX, KJ-T300 Use U-O
50Hz 220,240V single phase V-O
W-O
50Hz 220,380,415V 3 phase Use U-V-W
¤) KJ-T160DX, KJ-T210VX Use U-O
60Hz 127,220V single phase V-O
W-O
60Hz 220,380V 3 phase Use U-V-W
(1) Light
(2) Motor