3
ENGLISH
SPECIFICATIONS
쎱 General Type (60Hz)
Unit
kVA
kW
%
V
A
Hz
rpm
ºC
mm
kg
mm
mL
kW (PS)
L/h
L
L
L
(V x AH/5Hr)
Model
Generator
Generator type
Type
Rated output
No. of phase
Power factor
Rating
Rated voltage
Current
Rated frequency
Insulation class
Excitation
No. of poles
Drive
Engine speed
Ambient
temperature range
Length x Width
x Height
Mass
Engine
Model
Type
Cylinders – Bore x
Stroke
Displacement
Rated output
Fuel
Fuel consumption
Fuel tank capacity
Engine oil grade
Engine oil capacity
Coolant capacity
Battery capacity
Emergency stop
system
KJ-S150VX KJ-T160DX KJ-T210VX
PX-316KU1 PX-312KU3 PX-316KU3
Revolving field, self-excited brushless AC generator
15.0 15.6 21.0
15.0 12.5 16.8
1 Phase 4 wires 3 Phases 12 wires
100 80
Continuous
110/220 120/240 220 380 220 380
68.2 62.5 40.9 23.7 55.1 31.9
60
H
Self-excitation
4
Direct drive
1800
–15 to 40
1488 x 650 x 971 1393 x 650 x 971 1488 x 650 x 971
505 450 505
V2203 D1703 V2203
Vertical water cooled 4 cycle diesel
4 – 87 x 92.4 3 – 87 x 92.4 4 – 87 x 92.4
2197 1647 2197
19.9 (27.1) 14.9 (20.3) 19.9 (27.1)
Diesel fuel No. 2-D (ASTM D975)
6.3 4.7 6.2
37
API service class CD or higher
7.6 5.6 7.6
9.0 8.0 9.0
95D31R (12 x 64)
In case of abnormal Oil Pressure or water temperature
Including the reserve tank