VIII− Troubleshooting Guide SureLight Control
UPON INITIAL POWER UP, REMOVE ALL THERMOSTAT DEMANDS TO THE UNIT
Unless otherwise noted, condition applies to all G32 units.
PROBLEM: 1 UNIT FAILS TO OPERATE IN THE COOLING, HEATING, OR CONTINUOUS FAN MODE
Condition Possible Cause Corrective Action / Comments
1.1
Both diagnostic lights fail to light up.
1.1.1
Main voltage 120V not supplied to unit.
ACTION 1 − Check 120V main voltage.
Determine cause of main power failure.
LED#1−Off
LED#2−Off
1.1.2
Miswiring of furnace or improper con
nections.
ACTION 1 − Check for correct wiring of 120V to
power make up box and transformer.
ACTION 2 − Check 24V wiring to control board.
1.1.3
Circuit breaker tripped or fails to
close.
ACTION 1 − Replace circuit breaker if it is reset
but does not have continuity.
ACTION 2 − If circuit breaker still trips, check for
short.
1.1.4
Door interlock switch failure.
ACTION 1 − Check that door switch is activated
when door is closed.
ACTION 2 Check wire connections to switch, re
place loose connectors.
ACTION 3 − Check continuity of switch in closed
position. Replace if malfunctioning
1.1.5
Transformer Failure.
ACTION 1 − Check that transformer output is
24V. Replace if malfunctioning
1.1.6
Failed control board.
ACTION 1 − If all the above items have been
checked, replace board.
1.2
G32−1 through −3 Units Only
Diagnostic lights flash the roll−out
1.2.1
Roll−out switch open.
ACTION 1 − Manually reset the roll−out switch
by pushing the top button.
ACTION 2 − Determine the cause of the roll−out
switch activation before leaving furnace.
Diagnostic
lights
flash
the
roll out
code.
1.2.2
Roll−out switch failure.
ACTION 1 − Check continuity across roll−out
switch. Replace roll−out switch if switch is reset
but does not have continuity.
LED#1
On,
1.2.3
Mis iring or improper connections at
ACTION 1 Check wiring connections to switch
LED#1
On
,
LED#2−Slow Flash
Miswiring or improper connections at
roll−out switch.
ACTION
1
Ch
ec
k
w
i
r
i
ng connect
i
ons to sw
i
tc
h
.
1.2.4
Nine pin connector failure
ACTION 1 − Check 9−pin connector for proper
connection to control board.
ACTION 2 − Check continuity of the multi plug
pin.
1.3
− On initial power−up the comb. air
b
l
o
w
e
r
does
n
ot
e
n
e
r
g
iz
e
.
blower
does
not
energize
.
− Diagnostic lights flash the reverse
polarity code.
1.3.1
120V main power polarity reversed.
ACTION 1 − Check the 120V has line and neutral
correctly input into control.
ACTION 2 − Reverse the line and neutral at the
120V field connection.
LED#1−Fast Flash,
LED#2−Slow Flash.
120V
field
connection
.
1.4
G32−1 through −3 Units Only
− On initial power up the combustion
air blower does not energize.
− Diagnostic lights flash normal power
on operation
1.4.1
Open combustion air blower motor cir
cuit.
ACTION 1 − Check for 120V to combustion air
blower. If no power, check wire and connec
tions.
on operat
i
on.
LED#1−Slow Flash
LED#2−Slow Flash
1.4.2
Failed combustion air blower motor.
ACTION 1 − If power is present at blower, replace
blower.

Other manuals for Lennox G32 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox G32 SERIES and is the answer not in the manual?

Lennox G32 SERIES Specifications

General IconGeneral
BrandLennox
ModelG32 SERIES
CategoryFurnace
LanguageEnglish

Related product manuals