EasyManuals Logo
Home>Lennox>Heat Pump>HP25 Series

Lennox HP25 Series User Manual

Lennox HP25 Series
12 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Page 12
HP25 CHECK POINTS
START-UP AND PERFORMANCE CHECK LIST
Job Name
Job Location
Installer
Unit Model No.
Nameplate Voltage
Minimum Circuit Ampacity
Maximum Overcurrent Protection Size
Refrigerant Lines:
Service Valves Backseated?
Outdoor Fan Checked?
Job No.
City
City
Serial No.
Date
State
State
Service Technician
Amps:
Supply Outdoor Fan
Compressor
Indoor Filter Clean?
Indoor Blower RPM
Electrical Connections Tight?
Supply Voltage (Unit Off)
S.P. Drop Over Evaporator (Dry)
Outdoor Entering Air Temperature
Discharge Pressure Suction Pressure
COOLING SECTION
THERMOSTAT
Refrigerant Charge Checked?
Calibrated? Properly Set?
Level?
Properly Insulated?
Voltage With Compressor Operating
Leak Checked?
Service Valve Caps Tight?

Questions and Answers: