VI−MAINTENANCE
WARNING
Electric shock hazard. Can cause injury
or death. Before attempting to perform
any service or maintenance, turn the
electrical power to unit OFF at discon
nect switch(es). Unit may have multiple
power supplies.
At the beginning of each heating or cooling season, the
system should be cleaned as follows:
A−Outdoor Unit
1− Clean and inspect condenser coil. (Coil may be
flushed with a water hose).
2− Visually inspect all connecting lines, joints and coils for
evidence of oil leaks.
IMPORTANT
If insufficient heating or cooling occurs, the unit
should be gauged and refrigerant charge
checked.
B−Indoor Coil
1− Clean coil if necessary.
2 Check connecting lines and coil for oil leaks.
3−Check condensate line and clean if necessary.
C−Indoor Unit
1− Clean or change filters.
2− Adjust blower cooling speed. Check static pressure drop
over coil to determine correct blower CFM. Refer to Len
nox Engineering Handbook.
3− Belt Drive BlowersCheck condition/tension.
4− Check all wiring for loose connections.
5− Check for correct voltage at unit.
6− Check amp−draw on blower motor.
Unit nameplate_________Actual_________.