EasyManuals Logo
Home>Lennox>Air Conditioner>MCA Series

Lennox MCA Series Installation Instructions

Lennox MCA Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION
INSTRUCTIONS
©
2018 Lennox Industries Inc.
Dallas, Texas, USA
WARNING
Improper installation, adjustment, alteration, ser vice
or maintenance can cause property damage, personal
injury or loss of life.
Installation and service must be performed by a li-
censed professional HVAC installer (or equivalent) or a
service agency.
CAUTION
In order to avoid injury, take proper precaution when
lifting heavy objects.
General
Refer to the Product Specications bulletin (EHB) for more
product information. These instructions are intended as
a general guide and do not supersede local or national
codes in any way. Authorities having jurisdiction should
be consulted before installation.
This wall-mounted indoor unit is matched with an outdoor
air conditioner unit to create a mini-split system that uses
HFC-410A refrigerant.
Use of Mini-Split System During
Construction
Lennox does not recommend the use of its mini-split
systems during any phase of construction. Very low return
air temperatures, harmful vapors and operation of the unit
with clogged or misplaced lters will damage the system.
However, mini-split systems may be used for cooling of
buildings under construction, if the following conditions
are met:
Air lter must be installed in the system and must be
maintained during construction.
Air lter must be replaced upon construction comple-
tion.
The indoor wall unit assembly must be thoroughly
cleaned following nal construction clean-up.
All mini-split operating conditions must be veried ac-
cording to these installation instructions.
MCA Series Units
SINGLE-ZONE MINI-SPLIT SYSTEM
(115V and 208/230V)
507879-01 6/2019
Supersedes 11/2018
Table of Contents
General ...........................................................................1
Use of Mini-Split System During Construction................1
Included Parts.................................................................2
Model Number Identication ...........................................3
Typical System Components ..........................................4
System Dimensions ........................................................4
Outdoor Units ..............................................................4
Indoor Units .................................................................5
Indoor Unit Wall Mounts ..............................................5
System Clearances ........................................................5
Outdoor Unit ................................................................5
Multiple Outdoor Units .................................................6
Indoor Unit ...................................................................6
Torque Requirements for Caps and Fasteners...............7
Indoor Unit Installation ....................................................7
Unit Placement Considerations ...................................7
Determining Wall Mounting Plate Location ..................7
Installation of Wall Mounting Plate...............................7
Installation of Wall Sleeve............................................8
Installation of Indoor Unit on Wall Mounting Plate .......8
Indoor Unit Condensate Piping Connections ...............8
Outdoor Unit Installation .................................................9
Placement Considerations ...........................................9
Direct Sunlight and Rain Protection .............................9
Buried Refrigerant Pipe Protection ............................10
Securing the Outdoor Unit .........................................10
Refrigerant Piping Connections ....................................10
Adding Refrigerant for Longer Line Set ........................12
Leak Test and Evacuation ............................................12
Leak Test ...................................................................12
Triple Evacuation Procedure......................................13
Wiring Connections ......................................................13
Outdoor Unit .............................................................13
Indoor Unit .................................................................13
Wiring Diagrams (Outdoor Units) ..............................15
Wiring Diagrams (Indoor Units) .................................16
Unit Start-Up .................................................................18
Troubleshooting ............................................................18
Test Run .......................................................................18
Pre-Checks ................................................................18
Procedure ..................................................................18
Test Run Checklist ........................................................18
Double-Check Line Set Connections............................18
Ambient Temperature is Below 63ºF (17ºC) .................19
THIS MANUAL MUST BE LEFT WITH THE OWNER
FOR FUTURE REFERENCE

Other manuals for Lennox MCA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MCA Series and is the answer not in the manual?

Lennox MCA Series Specifications

General IconGeneral
BrandLennox
ModelMCA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals