FIGURE 49
ML193UHE with Evaporator Coil Using a Separate Drain
(Unit shown in horizontal left-hand discharge position)
.
5’ max.
PVC Pipe Only
4”min
5”max
Evaporator
Coil
Drain
Pan
Condensate
DrainConnection
Field Provided Vent
(4” min. to 5” max. above
condensate connection)
*Piping from furnace and evaporator coil must
slope down a minimum 1/4” per ft. toward trap
(Trap at coil is optional)
FIGURE 50
ML193UHE with Evaporator
Coil Using a Common Drain
(1” min. to 2” Max.above
condensate drain connection)
Condensate
DrainConnection
Evaporator drain
line required
(Trap at coil is optional)
IMPORTANT
When combining the furnace and evaporator
coil drains together, the A/C condensate drain
outlet must be vented to relieve pressure in or
der for the furnace pressure switch to operate
properly.
FIGURE 51
ML193UHE with Evaporator Coil Using a Common Drain
(Unit shown in horizontal lefthand discharge position)
(4” min. to 5” Max.above
condensate drain connection)
5’ max.
PVC Pipe Only
4”min
5”max
Evaporator
Coil
Drain
Pan
(Trap at coil is optional)
Condensate
DrainConnection
*Piping from furnace and evaporator coil must
slope down a minimum 1/4” per ft. toward trap

Table of Contents

Other manuals for Lennox ML193UH090XE48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ML193UH090XE48C and is the answer not in the manual?

Lennox ML193UH090XE48C Specifications

General IconGeneral
BrandLennox
ModelML193UH090XE48C
CategoryFurnace
LanguageEnglish

Related product manuals