EasyManuals Logo
Home>Lennox>Furnace>ML193UHE Series

Lennox ML193UHE Series User Manual

Lennox ML193UHE Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Page 17
C- Blower Compartment
IMPORTANT
Each blower is statically and dynamically balanced
as an assembly before installation in the unit.
EL196UHE units are equipped with a constant torque ECM
motor. It has a DC motor coupled to an electronic control
module both contained in the same motor housing. The mo
tor is programmed to provide constant torque at each of the
five selectable speed taps. Each tap requires 24 volts to en
ergize.
Input Voltage Requirements
The circuit is designed to be operated with AC voltage. To
enable a tap requires 12 to 33VAC. Expected current draw
will be less than 20mA.
Troubleshooting the Motor
Troubleshooting the motor is an easy process. Follow
steps below.
1- Shut off power to unit.
2- Remove input plugs P48 and P49 from motor. See
figure 15 for troubleshooting procedure.
If correct voltage is present in tests 1 and 2 and motor is not
operating properly, replace motor. The motor is not field re
pairable.
If replacing the indoor blower motor or blower wheel is nec
essary, placement is critical. The blower wheel must be cen
tered in the blower housing as shown in figure 12. When re
placing the indoor blower motor the set screw must be
aligned and tightened with the motor shaft as shown in figure
13.
9. Secondary Limit Controls
The secondary limit is located in the blower compartment on
the back side of the blower housing. See figure 14. When ex
cess heat is sensed in the blower compartment, the limit will
open. If the limit is open, the furnace control energizes the sup
ply air blower and closes the gas valve. The limit automatically
resets when unit temperature returns to normal. The sec
ondary limit cannot be adjusted.
FIGURE 12
Center Blower Wheel
in Blower Housing
BLOWER WHEEL REPLACEMENT
FIGURE 13
Set Screw
Housing Hub
ALIGN AND TIGHTEN SET SCREW WITH
FLAT SIDE OF MOTOR SHAFT
Motor
Shaft
FIGURE 14
SECONDARY LIMIT CONTROL
Secondary Limits

Table of Contents

Other manuals for Lennox ML193UHE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ML193UHE Series and is the answer not in the manual?

Lennox ML193UHE Series Specifications

General IconGeneral
BrandLennox
ModelML193UHE Series
CategoryFurnace
LanguageEnglish

Related product manuals