FIGURE 8
Measuring Flame Signal
Flame Signal In Microamps
Normal Low Drop Out
1.5
0.5 - 1.4
0.4
Set Dial to DC MicroAmps
(+)
MultiMeter
(+)
(+) To Control
Sensor Terminal
() T
o Flame
Terminal
Flame Sensor
Terminal
Flame Sensor
Wire
Intergrated
Control
Remove sensor from integrated
control and connect alligator clip
() to flame sensor lead.
Remove sensor from integrated
control and connect alligator clip
(+) to terminal on control.