Page 2
SPECIFICATIONS
Gas
Heating
Performance
Model No.
ML196UH
030XE36B
ML196UH
045XE36B
ML196UH
070XE36B
ML196UH
070XE48B
ML196UH
090XE36C
1
AFUE 96% 96% 96% 96% 96%
Input - Btuh 30,000 44,000 66,000 66,000 88,000
Output - Btuh 29,000 42,800 63,900 63,900 85,600
Temperature rise range - °F 25 - 55 35 - 65 35 - 65 30 - 60 45 - 75
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10 3.5 / 10 3.5 / 10 3.5 / 10 3.5 / 10
High static - in. w.g. 0.5 0.5 0.5 0.5 0.5
Energy Star
®
Certied Yes Yes Yes Yes Yes
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nom. dia. x width - in. 10 x 8 10 x 8 10 x 8 11-1/2 x 10 10 x 8
Motor Type DC Brushless DC Brushless DC Brushless DC Brushless DC Brushless
Motor output - hp 1/2 1/2 1/2 3/4 1/2
Tons of add-on cooling 1.5 - 3 1.5 - 3 1.5 - 3 2 - 4 1.5 - 3
Air Volume Range - cfm 175 - 1435 520 - 1345 550 - 1380 500 - 1710 460 - 1470
Electrical Data Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 6.8 6.8 6.8 8.4 6.8
Maximum overcurrent protection 15 15 15 15 15
Shipping Data lbs. - 1 package 120 124 129
XXX XXX
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Eciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No.
ML196UH
090XE48C
ML196UH
090XE60C
ML196UH
110XE60C
ML196UH
135XE60D
1
AFUE 96% 96% 96% 96%
Input - Btuh 88,000 88,000 110,000 132,000
Output - Btuh 85,600 85,600 107,200 127,000
Temperature rise range - °F 50 - 80 35 - 65 45 - 75 45 - 75
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10 3.5 / 10 3.5 / 10 3.5 / 10
High static - in. w.g. 0.5 0.5 0.5 0.5
Energy Star
®
Certied Yes Yes Yes Yes
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 3/4
with furnished 90° street elbow 3/4 slip x 3/4 Mipt
with eld supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT
Indoor
Blower
Wheel nom. dia. x width - in. 10 x 10 11 x 11 11-1/2 x 10 11 x 11
Motor Type DC Brushless DC Brushless DC Brushless DC Brushless
Motor output - hp 3/4 1 1 1
Tons of add-on cooling 2.5 - 4 3-5 3 - 5 3-5
Air Volume Range - cfm 760 - 1740
XXX 1055 - 2220 1310 - 2400
Electrical Data Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 8.4 10.9 10.9 10.9
Maximum overcurrent protection 15 15 15 15
Shipping Data lbs. - 1 package 152
XXX 164 XXX
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Eciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.