Error Code: P4
Description: Compressor drive error
General Note: An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection,
voltage detection, compressor rotation speed signal detection and etc
CompressorDriveError
Checkwiringconnectionsbetweencompressorand
mainPCB.
No
Makenecessarycorrections.
Yes
ChecktheIPM
ReplacetheIPMboardorreplacethe
mainPCB.
No
Yes
Checktheoutdoorfanandtheoutdoorunitventilation.
Refertotheerrorcodefanspeedmal-
function (E8).
No
Yes
Checkthecompressorresistancevalues.
Replacethecompressor.
No
Yes
ReplacetheoutdoormainPCB.
Error Code: P5
Description: Modeconict.
General Note: Theindoorunitscannotworkcoolingmodeandheatingmodeatthesametime.Heatingmodehaspriority.
SupposeindoorunitAworkingincoolingmodeorfanmode,andindoorunitBissettoheatingmode,thenAwillchange
tooffandBwillworkinheatingmode.
SupposeindoorunitAworkinginheatingmode,andindoorunitBissettocoolingmodeorfanmode,thenBwillchange
tostandbyandAwillbenochange.
Cooling mode Heating mode Fan Off
Cooling Mode No Yes No No
Heating Mode Yes No Yes No
Fan No Yes No No
Off No No No No
No=Nomodeconict.
Yes=Modeconict

Table of Contents

Other manuals for Lennox MLA030S4M-*P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MLA030S4M-*P and is the answer not in the manual?

Lennox MLA030S4M-*P Specifications

General IconGeneral
BrandLennox
ModelMLA030S4M-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals