EasyManuals Logo
Home>Lennox>Air Conditioner>MPA018S4M-*P

Lennox MPA018S4M-*P User Manual

Lennox MPA018S4M-*P
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
90
19. Start-Up
19.1. Adding Refrigerant - Single-Zone Systems
Theoutdoorunitisfactory-chargedwithrefrigerant.Calculatetheadditionalrefrigerantrequiredaccordingtothediameter
andthelengthoftheliquidpipebetweentheoutdoorunitandindoorunitconnections.
Besuretoaddtheproperamountofadditionalrefrigerant.Failuretodosomayresultinreducedperformance.
NOTE: Interconnecting pipe work between outdoor and indoor units must be 10 ft. or longer.
NOTE: Do not remove refrigerant for line lengths less than 25 ft. R-410A is a blended refrigerant. If you must remove
charge, it is necessary to remove the entire charge and weigh in the new charge.
Table 1. Adding Refrigerant
System Size (KBtu)
Pipe Length Amount of Refrigerant to add
09 >25 ft. (7.5m) 0.161oz/ft(15g/m)
12 >25 ft. (7.5m) 0.161oz/ft(15g/m)
18 >25 ft. (7.5m) 0.161oz/ft(15g/m)
24 >25 ft. (7.5m) 0.322oz/ft(30g/m)
36 >25 ft. (7.5m) 0.322oz/ft(30g/m)
48 >25 ft. (7.5m) 0.322oz/ft(30g/m)
19.2. Adding Refrigerant - Multi-Zone Systems
Theoutdoorunitisfactory-chargedwithrefrigerant.Calculatetheadditionalrefrigerantrequiredaccordingtothelengthof
theliquidpipe(oneway)betweentheoutdoorunitandindoorunitconnections.
Besuretoaddtheproperamountofadditionalrefrigerant.Failuretodosomayresultinreducedperformance.
NOTE: Interconnecting pipe work between outdoor and indoor units must be 10 ft. or longer.
NOTE: Do not remove refrigerant for line lengths less than 25 ft. R-410A is a blended refrigerant. If you must remove
charge, it is necessary to remove the entire charge and weigh in the new charge.
Table 2. Adding Refrigerant
System
Pre-charge
Pipe Length
Amount of Refrigerant to add
Two-port 50 ft. (15 m)
0.16oz((L1ft+L2ft)-50ft)
0.005kg((L1m+L2m)-15m)
Three-port 75 ft. (23 m)
0.16oz((L1ft+L2ft+L3ft)-75ft)
0.005kg((L1m+L2m+L3m)-23m)
Four-port 100 ft. (30 m)
0.16oz((L1ft+L2ft+L3ft+L4ft)-100ft)
0.005kg((L1m+L2m+L3m+L4m)-30m)
Five-port 125 ft. (38 m)
0.16oz((L1ft+L2ft+L3ft+L4ft+L5ft)-125ft)
0.005kg((L1m+L2m+L3m+L4m+L5m)-38m)

Table of Contents

Other manuals for Lennox MPA018S4M-*P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MPA018S4M-*P and is the answer not in the manual?

Lennox MPA018S4M-*P Specifications

General IconGeneral
BrandLennox
ModelMPA018S4M-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals