EasyManuals Logo
Home>Lennox>Air Conditioner>MPA048S4S-1P

Lennox MPA048S4S-1P User Manual

Lennox MPA048S4S-1P
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Lennox Mini-Split Service Manual / Page 16
SPECIFICATIONS - 1.5 - 2.5 TON MPA OUTDOOR UNITS
Nominal Size - Tons 1.5 2.5
Outdoor Unit Model No. MPA018S4M-1P MPA030S4M-1P
Number of Zones 2 Up to 3
1
AHRI
Ratings
System Type Ducted Non-Ducted Ducted Non-Ducted
Cooling - Btuh 17,000 18,000 27,000 25,000
High Temperature Heating - Btuh 18,000 18,500 32,000 32,000
Low Temperature Heating - Btuh 10,900 11,000 20,000 20,000
SEER 18.00 21.00 16.50 22.00
EER 12.50 12.50 9.50 12.50
HSPF (Region IV) 8.5 9.6 8.8 9.6
AHRI Reference Number 8129621 8129607 8129624 8129613
Energy Star Yes No
Ambient Temperature Range - °F Cooling 5 - 122 5 - 122
Heating –13 - 76 –13 - 76
Sound Data (dBA) Cooling 57 59
Heating 62 62
Refrigerant Charge furnished (R-410A) 4 lbs. 4 oz. 6 lbs. 3 oz.
Maximum line length with furnished charge (per zone) - ft. 25 25
Additional charge required per ft. - oz. 0.161 0.161
Compressor No. and Type Twin-Rotary Twin-Rotary
Refrigerant oil type ESTER OIL VG74 ESTER OIL VG74
Refrigerant oil charge - oz. 16.9 27.7
Low ambient cut-off
Connections - in. Liquid+Gas pipe ( are) (2) 1/4 + (2) 3/8 (3) 1/4 + (3) 3/8
Maximum length for all rooms - ft. 98 148
Maximum length for one indoor unit - ft. 66 82
Maximum height
difference between
indoor unit and
outdoor unit
Outdoor unit higher than indoor
unit - ft.
33 33
Outdoor unit lower than indoor
unit - ft.
49 49
Maximum difference in level between indoor units - ft. 33 33
Outdoor
Fan
(No.) Diameter - in. (1) - 18 (1) - 22
Total air volume - cfm 1470 2060
rpm 750 850
Outdoor Coil Number of rows 2 1.6
Fins per inch 14 15
Fin type Hydrophilic aluminium
Tube outside diameter - in. 3/8 3/8
Tube type Ri ed copper tubing
Net face area - ft.
2
4.9 6.42
Design Pressure PSIG 550/340 550/340
Shipping Data Net/Shipping weight (lbs.) 106 / 115 144 / 155
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase 208/230V 208/230V
2
Maximum Overcurrent Protection (amps) 20 25
3
Minimum circuit ampacity 15 19
Compressor Rated load amps 10 12
Outdoor Fan Motor Rated load amps 0.74 0.90
Output - W 50 120
NOTE - Per AHRI, the certi ed ratings for systems are valid for all combinations of indoor units with the speci c outdoor units listed above and in the AHRI Directory of
Certi ed Equipment. Please visit http://www.ahridirectory.org for further details and latest updates.
1
Ratings are AHRI certi ed to AHRI Standard 210/240-2008;
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Adaptors are furnished for the gas pipe connections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.

Table of Contents

Other manuals for Lennox MPA048S4S-1P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MPA048S4S-1P and is the answer not in the manual?

Lennox MPA048S4S-1P Specifications

General IconGeneral
BrandLennox
ModelMPA048S4S-1P
CategoryAir Conditioner
LanguageEnglish

Related product manuals