47
9. MPA, MPB and MLA Outdoor Unit
Connections and Line Set Usage
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MPA018S4M
MPB018S4M
Indoor๎Unit๎A
1/4โ๎liq๎+๎3/8โ๎gas
Indoor๎Unit๎B
1/4โ๎liq๎+๎3/8โ๎gas
1 012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
009 (A) 1/4๎in.๎x๎3/8๎in.
009๎(B) 1/4๎in.๎x๎3/8๎in.
2
009๎(B) 1/4๎in.๎x๎3/8๎in.
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
MPA030S4M
MPB030S4M
Indoor๎Unit๎A
1/4โ๎liq๎+๎3/8โ๎gas
Indoor๎Unit๎B
1/4โ๎liq๎+๎3/8โ๎gas
Indoor๎Unit๎C
1/4โ๎liq๎+๎3/8โ๎gas
1 018 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
009 (A) 1/4๎in.๎x๎3/8๎in.
009๎(B) 1/4๎in.๎x๎3/8๎in.
2
009๎(B) 1/4๎in.๎x๎3/8๎in.
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
009๎(B) 1/4๎in.๎x๎3/8๎in.
018 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
2
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
018 (A)
1
๎1/4๎in.๎x๎1/2๎in.
2
018 (A)
1
๎1/4๎in.๎x๎1/2๎in.
018๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
009 (A) 1/4๎in.๎x๎3/8๎in.
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
3
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
3
009 (C) 1/4๎in.๎x๎3/8๎in.
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
018 (A)
1
๎1/4๎in.๎x๎1/2๎in.
3
012 (A)
1
๎1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
012 (C)
1
๎1/4๎in.๎x๎1/2๎in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished๎with๎outdoor๎unit).
2
๎๎1/4๎x๎3/8๎in.๎liquid๎pipe๎adaptor๎is๎required๎for๎line๎set๎connection๎to๎the๎048๎
outdoor๎unit๎(furnished๎with๎outdoor๎unit).
3
๎๎1/2๎x๎5/8๎in.๎gas๎pipe๎adaptor๎is๎required๎for๎line๎set๎connection๎to๎the๎048๎outdoor๎
unit๎(furnished๎with๎outdoor๎unit).
4
๎๎Not๎a๎valid๎combination๎when๎using๎the๎MPA036S4M.
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MPA036S4M
MPB036S4M
Indoor๎Unit๎A
1/4โ๎liq๎+๎1/2โ๎gas
Indoor๎Unit๎B
1/4โ๎liq๎+๎3/8โ๎gas
Indoor๎Unit๎C
1/4โ๎liq๎+๎3/8โ๎gas
Indoor๎Unit๎D
1/4โ๎liq๎+๎3/8โ๎gas
2
009๎(B)
018 (A)
1/4๎in.๎x๎3/8๎in.
1/4๎in.๎x๎1/2๎in.
2
4
009๎(B)
024๎(A)
1/4๎in.๎x๎3/8๎in.
2,3
3/8 in. x 5/8 in.
2
012 (A)
012๎(B)
1/4๎in.๎x๎1/2๎in.
1
๎1/4๎in.๎x๎1/2๎in.
2
4
012๎(B)
024๎(A)
1
๎1/4๎in.๎x๎1/2๎in.
2,3
3/8 in. x 5/8 in.
2
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
2
018 (A) 1/4๎in.๎x๎1/2๎in.
018๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
009๎(D) 1/4๎in.๎x๎3/8๎in.
3
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
012 (A) 1/4๎in.๎x๎1/2๎in.
3
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
3
009 (C) 1/4๎in.๎x๎3/8๎in.
012 (A) 1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
009 (C) 1/4๎in.๎x๎3/8๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
3
009 (C) 1/4๎in.๎x๎3/8๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
018๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
012 (A) 1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
012 (C)
1
๎1/4๎in.๎x๎1/2๎in.
3
012 (C)
1
๎1/4๎in.๎x๎1/2๎in.
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
3
012 (C)
1
๎1/4๎in.๎x๎1/2๎in.
018 (A) 1/4๎in.๎x๎1/2๎in.
018๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
3
4
012๎(B)
1
๎1/4๎in.๎x๎1/2๎in.
012 (C)
1
๎1/4๎in.๎x๎1/2๎in.
024๎(A)
2,3
3/8 in. x 5/8 in.
4
009๎(B) 1/4๎in.๎x๎3/8๎in.
009 (C) 1/4๎in.๎x๎3/8๎in.
009๎(D) 1/4๎in.๎x๎3/8๎in.
009 (A)
1
๎1/4๎in.๎x๎3/8๎in.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished๎with๎outdoor๎unit).
2
๎๎1/4๎x๎3/8๎in.๎liquid๎pipe๎adaptor๎is๎required๎for๎line๎set๎connection๎to๎the๎048๎
outdoor๎unit๎(furnished๎with๎outdoor๎unit).
3
๎๎1/2๎x๎5/8๎in.๎gas๎pipe๎adaptor๎is๎required๎for๎line๎set๎connection๎to๎the๎048๎outdoor๎
unit๎(furnished๎with๎outdoor๎unit).
4
๎๎Not๎a๎valid๎combination๎when๎using๎the๎MPA036S4M.