Page 2
SPECIFICATIONS − O23
Model Number O23Q270 O23Q3105/120 O23Q5140/154
InputBtuh (kW) low/high 70,000 (20.5) 105,000 / 120,000(30.8 / 35.2) 140,000 / 154,000(41.0 / 45.1)
Output Btuh (kW) low/high 57,000 (16.7) 85,000 / 97,000 (24.9 / 28.4) 113,000 / 125,000 (33.1 / 36.6)
*A.F.U.E. 83.8% 82.8% (105) / 82.5% (120) 82.5% (140) / 81.4% (154)
Nozzle Rating gph (L/hr) and spray angle .50 (1.9) 80°hollow
.65 (2.5) 80° (105 input) solid
.75 (2.8) 80°(120 input) solid
.85 (3.2) 80° (140 input) solid
1.00 (3.8) 80° (154 input) solid
Flue Size Diameterin. (mm) 6 (152) 6 (152) 6 (152)
Oil Burner Pump 1 Stage 1 Stage 1 Stage
Oil Burner Pump Pressure psig (Pa) 100 (690) 140 (965) 140 (965)
Blower wheel nominal
in. 10 x 6 10 x 8 12 x 9
diameter x width
mm 254 x 152 254 x 203 305 x 229
Blower Motor Output hp (W) 1/3 (249) 1/3 (249) 3/4 (560)
Nominal cooling that can be added
Tons 2 thru 2.5 2 thru 3.5 3 thru 5
Nominal cooling that can be added
kW 7.0 thru 8.8 7.0 thru 12.3 10.6 thru 17.6
**Number and size of filtersin. (mm) (1) 16 x 25 x 1 (1) 16 x 25 x 1 (2) 16 x 25 x 1
Shipping weight lbs. (kg) 1 package 225 (102) 225 (102) 275 (125)
Electrical characteristics 115 volts 60 hertz 1 phase
Optional Accessories (Must Be Ordered Extra)
Two Stage Oil Pump 65A44
Oil Filter 81P89
*Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and FTC labeling regulations. Isolated combustion system rating for nonweatherized furnaces.
**Cleanable frame type filters. Furnished with unit in Side Filter Adaptor Kit for field installation external to the cabinet.
Requires return air from both sides of cabinet.
Nozzle must be field provided for field conversion to higher heating input.
SPECIFICATIONS − OHR23
Model Number OHR23Q3105/120 OHR23Q5140/154
InputBtuh (kW) low/high 105,000 / 120,000(30.8 / 35.2) 140,000 / 154,000(41.0 / 45.1)
OutputBtuh (kW) low/high 85,000 / 97,000 (24.9 / 28.4) 113,000 / 125,000 (33.1 / 36.6)
*A.F.U.E. (low/high) 81.8% / 81.3% 81.5% / 81.7%
Nozzle RatingU.S. gph (L/hr)
and spray angle
.65 (2.5) 80 (105 input) solid
.75 (2.8) 80 (120 input) solid
.85(3.2) 80(140 input) solid
1.00 (3.8) 80 (154 input) solid
Flue Size Diameterin. (mm) 6 (152) 6 (152)
Oil Burner Pump 1 Stage 1 Stage
Oil Burner Pump Pressure psig (Pa) 140 (965) 140 (965)
Blower wheel nominal diameter x width in. (mm) 10 x 10 (254 x 254) 12 x 9 (305 x 229)
Blower motor outputhp (W) 1/2 (373) 3/4 (560)
Nominal cooling that can be added
Tons 2 to 3 3 to 5
Nominal cooling that can be added
kW 7.0 to 10.6 10.6 to 17.6
Shipping weightlbs. (kg) 1 package 225 (102) 265 (120)
Electrical characteristics 115 volts 60 hertz 1 phase
Optional Accessories (Must Be Ordered Extra)
Two Stage Oil Pump 65A44
Catalog no. 35K01 35K06
ter
t
No & size of filters in (mm)
(2)101/4x201/2x1(260x521x25)
(2)113/4x231/2x1(298x597x25)
No. & size of filtersin. (mm) (2) 101/4 x 201/2 x 1 (260 x 521 x 25) (2) 113/4 x 231/2 x 1 (298 x 597 x 25)
Downflo Additive Base 35K07 35K08
Horizontal Venting Kit 62J01
Burner Cover 84H26
Vestibule Cover Kit (full front cover) 37K28 37K29
Oil Filter 81P89
*Annual Fuel Utilization Efficiency based on U.S. DOE test procedures and FTC labeling regulations. Isolated combustion system rating for nonweatherized furnaces.
Nozzle must be field provided for field conversion to higher heating input.