XP17 - 2 to 5 Ton Heat Pump / Page 12
SPECIFICATIONS
General
Data
Model No. XP17-024 XP17-030 XP17-036 XP17-042 XP17-048 XP17-060
Nominal Tonnage 2 2.5 3 3.5 4 5
Connections
(sweat)
Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 3/8 3/8
Vapor (Suction) line (o.d.) - in. 3/4 3/4 7/8 7/8 7/8 1-1/8
Refrigerant
1
R-410A charge furnished 10 lbs. 0 oz. 10 lbs. 2 oz. 10 lbs. 2 oz. 11 lbs. 0 oz. 14 lbs. 0 oz. 14 lbs. 8 oz.
Outdoor
Coil
Net face area
- sq. ft.
Outer coil 20.73 20.73 20.73 20.73 27.21 27.21
Inner coil 20.08 20.08 20.08 20.08 26.36 26.36
Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 5/16
No. of rows 2 2 2 2 2 2
Fins per inch 22 22 22 22 22 22
Outdoor
Fan
Diameter - in. 26.2 26.2 26.2 26.2 26.2 26.2
No. of blades 5 5 5 5 5 5
Motor hp 1/3 1/3 1/3 1/3 1/3 1/3
Cfm 2300 2600 3500 3500 4230 4230
Rpm 400 450 600 600 675 675
Watts 40 57 130 130 185 185
Shipping Data - lbs. 1 pkg. 287 287 288 312 349 356
ELECTRICAL DATA
Line voltage data - 60hz - 1 ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V
2
Maximum overcurrent protection (amps) 30 30 35 40 50 60
3
Minimum circuit ampacity 18.9 19.6 22.9 24.4 29.3 35.0
Compressor Rated load amps 13.5 14.1 16.7 17.9 21.8 26.4
Locked rotor amps 58.3 73.0 79.0 107.0 117.0 134
Power factor 0.99 0.99 0.97 0.92 0.96 0.96
Outdoor Fan Motor Full load amps 2 2 2 2 2 2
CONTROLS
icomfort Wi-Fi™ Thermostat 88W58
4
Remote Outdoor Temperature
Sensor (for dual fuel and Humiditrol
®
)
X2658
5
Discharge Temperature Sensor 88K38
ComfortSense
®
7000 Thermostat Y0349
Outdoor Temperature Sensor - for
ComfortSense 7000 Thermostat
X2658
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Hard Start Kit
88M91
Compressor Low Ambient Cut-Off
45F08
Freezestat
3/8 in. tubing 93G35
5/8 in. tubing 50A93
Low Ambient Kit
68M04
Indoor Blower Off Delay Relay
58M81
Mild Weather Kit
33M07
Monitor Kit - Service Light
76F53
Outdoor
Thermostat Kit
Thermostat 56A87
Mounting Box 31461
Refrigerant
Line Sets
L15-41-20 L15-41-40
L15-41-30 L15-41-50
L15-65-30 L15-65-40
L15-65-50
Field Fabricate
6
Snow Guards
X8782
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufcient for 15 ft. length of refrigerant lines.
2
HACR type breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Remote Outdoor Sensor may be used with an icomfort™-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional
outdoor unit.
5
Optional for service diagnostics.
6
Adds 11-1/2 inches (292 mm) to unit height.