Technical Data
3-2 UOMu_^MVMO
3.2 Rated data (Operation with 150 % overload)
3.2.1 Types 8201 to 8204
150 % overload Type 8201 8202 8203 8204
Order no. EVF8201-E EVF8202-E EVF8203-E EVF8204-E
Variant ”reduced assembly
d
t
h
Type 8202-V002
V
a
i
a
n
t
e
d
u
c
e
d
a
s
s
e
m
b
l
y
depth”
Order no. EVF8202-E- V002
Mains voltage V
rated
[V] 190V 0% V
rated
260V 0% ; 45Hz¼65Hz 0%
Alternative DC supply V
DC
[V] 270V 0% V
DC
360V 0%
Mains current
4)
with mains filter/mains choke
without mains filter/mains choke
I
mains
[A]
4.2
5.0
7.5
9.0
12.5
15.0
17.0
-
Data for mains operation with 1 AC / 230 V / 50 Hz/60 Hz; 270 V
DC
275V
Motor power (4 pole ASM)
t
9
2
k
H
P
rated
[kW] 0.37 0.75 1.5 2.2
o
t
o
p
o
e
(
p
o
e
S
)
at 9.2 k Hz*
P
rated
[hp] 0.5 1.0 2.0 2.9
Output power U, V, W
at 9.2 k Hz*
S
N9.2
[kVA] 1.0 1.5 2.7 3.6
Output power +U
G
,-U
G
1)
P
DC
[kW] 0.0 0.0 0.0 0.0
Output current I
rated
[A] 2.6 4.0 7.0 9.5
Max. output current for 60s
2)
I
Nmax
[A] 3.9 6.0 10.5 14.2
Motor voltage
3)
V
M
[V] 0-3× V
mains
/0Hz¼ 50Hz, if required up to 240Hz
Power loss (Operation with I
N
) P
v
[W] 30 50 70 100
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8200 series and is the answer not in the manual?

Lenze 8200 series Specifications

General IconGeneral
CategoryInverter
Output voltage range0 V to input voltage
Control modesvector control
Communication interfacesRS485, CANopen, Profibus, Ethernet
Protection featuresOvercurrent, overvoltage, undervoltage, short circuit, overtemperature
Relative humidity95 % (non-condensing)
Protection classIP20