Installation
UOMu_^MVMO 4-11
Terminal Use
(Factory setting is printed in bold)
Level Data
Analog
7 GND 1
inputs
8 Setpoint input,
reference:
Terminal 7
(0 to 10V)
S
Q
O
N
5-6
5-6
3-4
1-2
0to20mA
4to20mA
0to5V
0to10V
Resolution: 9 bit
Linearity fault:
±0.5 %
Temperature fault: 0.3 % (0...+40
°C)
Input resistance
Jumper
o
age s
gna
:>
Current signal: 250 Ω
9 Supply for setpoint potentiometer 5.2V / 6mA
Analog
output
62 Analog output, reference: terminal 7
(Field frequency)
0... 6 V / 2
mA
Resolution: 8 bit
Digital
inputs
20 Voltage supply for digital inputs
12 V/20 mA
28 Controller enable HIGH
HIGH: 12 V ... 30 V
E4 CW rotation/
CCW rotation (CW/CCW)
CW: LOW
CCW: HIGH
LOW:0V...3V
E3 DC-injection brake HIGH
E2
JOG frequencies Binary code
E1
20Hz, 30Hz, 40Hz
39 GND 2 (reference for external voltages)
Terminal Use
(Factory setting is printed in bold)
Relay position
(switched)
Data
Relay
output
K11 Relay output normally-closed contact
(TRIP)
opened
24 V AC / 3,0 A or
60 V DC / 0.5 A
K1
K12 Relay mid-position contact
K14 Relay output normally-open contact
(TRIP)
closed
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com