Troubleshooting and fault elimination
UOMu_^MVMO 8-1
8 Troubleshooting and fault elimination
D c~ìäíë ~êÉ áããÉÇá~íÉäó áåÇáÅ~íÉÇ îá~ íÜÉ Çáëéä~ó çê ëí~íìë
áåÑçêã~íáçå EÅÜ~éíÉê UKNFK
D qÜÉ Ñ~ìäí Å~å ÄÉ ~å~äóëÉÇ Äó ìëáåÖ íÜÉ Üáëíçêó ÄìÑÑÉê EÅÜ~éíÉê
UKOF ~åÇ íÜÉ äáëí áå ÅÜ~éíÉê UKPK qÜÉ äáëí ÜÉäéë óçì ïáíÜ íÜÉ
Éäáãáå~íáçå çÑ Ñ~ìäíëK
8.1 Troubleshooting
8.1.1 Display at the controller
aìêáåÖ çéÉê~íáçå ïáíÜçìí çéÉê~íáåÖ ãçÇìäÉI íÜÉ çéÉê~íáåÖ ëí~íÉ
çÑ íÜÉ ÅçåíêçääÉê áë Çáëéä~óÉÇ çå íïç ibaë íÜÉ Ñêçåí çÑ íÜÉ ìåáíK
LED Operating status
green red
on off Controller enabled
on on Mains switched on and automatic start inhibited (AS_LC)
blinking off Controller inhibited
off blinking every second Fault message, check under C161
off blinking every 0.4 seconds Undervoltage switch-off
off off Programming mode
8.1.2 Display at the operating module
pí~íìë áåÇáÅ~íáçåë áå íÜÉ Çáëéä~ó áåÇáÅ~íÉ íÜÉ ÅçåíêçääÉê ëí~íìëK
Display Meaning
OV Overvoltage
UV Undervoltage
IMAX Set current limit exceeded
TEMP Heat sink temperature near switch-off
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8203 and is the answer not in the manual?

Lenze 8203 Specifications

General IconGeneral
BrandLenze
Model8203
CategoryDC Drives
LanguageEnglish

Related product manuals