6
Operation
Remote parameterisation of system bus devices
EDK82ZBC DE/EN/FR 3.1
66
Parameter ändern u speichern----(DUMMYSEITEVOR)---
Remote parameterisation of system bus devices
If controllers are networked via systembus (CAN), you can set the parametersof all system bus nodes remotelyfrom
a central place of the network.
For this, use the function.
Note!
The system bus node can also be selected via C0370 instead of using the function.
Step
Key
sequence
Result Action
1.
Select function
o Change to function bar 2
2.

3.
Select address of the
node

1 ... 63 Select node address
4.
n
Confirm address and change to function bar 1
The node can be parameterised remotely.
5. Set parameters All settings are redirected to the node selected.
6. If required, further
system bus nodes can
be parameterised
remotely
Restart ”loop” with step 1.
Do not forget to switch off the remote parameterisation after completing the settings:
7.
Switch off remote
parameterisation
o Change to function bar 2
8.

9.
0 Switch off remote parameterisation
10.
n Confirm and change to function bar 1
The remote parameterisation is completed.