Technical data
General data/operating conditions
3
18
BA33.0001 EN 2.0
3 Technical data
3.1 General data/operating conditions
Field Values
Conformity CE Low-Voltage Directive (73/23/EEC)
Approvals UL 1004 Underwriter Laboratories (File No. E210321)
Climatic conditions Average relative humidity 85 %, without condensation
Permissible
Designs
temperature ranges
z
Non-ventilated or with integral
fan without brake or with
spring-operated brake
-20 °C ... +40 °C
Without power reduction, over
+40°C with power reduction, see
catalogue
z
With permanent magnet brake -10 °C ... +40 °C
z
With separate fan, without
permanent magnet brake
-15 °C ... +40 °C Without power reduction
Mounting positions Suitable for all mounting positions Vertical arrangements to DIN-IEC
34 Part 7 are possible if they meet
the designs
Protection type See nameplate Protection types only apply for
horizontal installation
Thermal class F (155 °C) to DIN-IEC 34 / VDE 0530 If the temperature limit is
exceeded, the insulation will be
damaged or destroyed
Tropical insulation Can not be guaranteed
Permissible installation
height h
h ≤ 1000 m AMSL
1000 m AMSL < h ≤ 4000 m AMSL
Without power reduction
With power reduction, see
catalogue
Permissible voltage 1.5 kV peak value 5kV/µsrateofrise
Vibration Up to 2.0g / 20m/s
2