Lexicon, Inc.
MC-12 Serial Communications Protocol Printed on: 08/18/03
© 2003 Lexicon, Inc. All rights reserved. 52 of 94
7.3.55 MC-12 Set Input Name by Id (MC-12)
Sets an Input Name to the transmitted value for a given input.
7.3.55.1 Command Packet Description
Application Header:
Command MC_CMD_SET_INPUT_NAME 0x48
Data Count
Number of characters in
InputName + 2 nn
Application Data:
Data[0] InputId 0 to 7
Data[1]-Data[DataCount-1] InputName ch ch ch ... 0x00
7.3.55.2 Data Description
InputId:
Data Type: Unsigned 8 bit Integer
Description/Conversion: Appendix F MC-12 Input Ids
InputName:
Data Type: Null (0x00) terminated ASCII character string.
Max Length: INPUT_NAME_LENGTH defined in Appendix G Protocol Constants.
7.3.55.3 MC-12 Response
MC-12 will copy the InputName to the given input.
7.3.55.4 Data Validation:
The InputId must be a valid Input Id. If it is not the MC-12 will respond with a NAK packet and error code
DC_INVALID_INPUT. If the InputName string exceeds the INPUT_NAME_LENGTH, the MC-12 will
truncate the string to the INPUT_NAME_LENGTH.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexicon MC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5 and is the answer not in the manual?

Lexicon MC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5 Specifications

General IconGeneral
BrandLexicon
ModelMC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5
CategoryComputer Hardware
LanguageEnglish

Related product manuals