EasyManuals Logo
Home>LG>Dryer>DLE5955W

LG DLE5955W Service Manual

LG DLE5955W
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
31
Changing orifices and gas valve adjustments improperly can result in an
explosion and/or fire. Conversion must be made by a qualified technician.
Initially
, Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
10
!
Warning
STEP 1 : VALVE SETTING
Closed
Opened
Full open
Adjustment screw
STEP 2 : ORIFICE CHANGE
Orifice
Gas type
Natural Gas
Propane Gas
Marking
NCU
PCU
Shape
Orifice P/No
4948EL4001B
4948EL4002B
Close
Adjustment screw
󳡉
Remove 2 screws.
󳡊
Disassemble the pipe assembly.
󳡋
Replace Natural Gas orifice with Propane Gas orifice.
Kit contents: Orifice (Dia. = 1.613mm, for Propane Gas)
Replace Label
Instruction Sheet

Other manuals for LG DLE5955W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG DLE5955W and is the answer not in the manual?

LG DLE5955W Specifications

General IconGeneral
BrandLG
ModelDLE5955W
CategoryDryer
LanguageEnglish

Related product manuals