SERVICE INFORMATION FOR EEPROM
POWER ON
Remote control ‘2’ + Front ‘STOP’
push same timing during 5s
Use arrow key ( ) move
to appropriate position and make
changes
Press ENTER key - ‘FLD’ write ‘OK’
Remote control ‘2’ + Front ‘STOP’
push same timing
FLD display E2P CLR→Auto power off
Completed option setting
Version Setting MODE
OPT 0 → ‘ OPT 0 - 00 ’
OPT 1
→ ‘ OPT 1 - 00 ’
OPT 2
→ ‘ OPT 2 - 00 ’
OPT 3
→ ‘ OPT 3 - 00 ’
OPT 4
→ ‘ OPT 4 - 00 ’