44
PROGRAMMING MODE
PROGRAMMING MODE - Collect Mode
Collect Information Data : CLCt (display)
The dryer collects the usage data so that the owner can check various information like number of various cycles
used, how many times card or coins used, etc.
Entering the collect mode
❖ Check the collect information reference to the follow lists. The Lists are displayed by abbreviations.
■ Collect Mode Data lists
Data Name Button Display Description
Entering
the collect
mode
1. Entering the
programming mode.
Insert service card(card type), Turn on/o toggle switch
(Coin type).
2. High Temp.
Press the High Temp. button until “tESt” appears in the
display.
3. Low Temp.
Press the Med Temp. or Low Temp. button until “CLCt”
appears in the display.
4. Start
Enter the Collect information data.
5. Med Temp. or Low
Temp.
Move to each data list that you want to check by pressing
with Med Temp. or Low Temp. button.
6. Start Display the value of selected data list
No.
Abbreviation
Meaning Description
1 rgPr Regular Price 0,00~9,90
2 rgCP Regular Cold Price rgCP is not available in dryer. (It can’t enter.)
3 rgrP Regular Warm Price rgrP is not available in dryer. (It can’t enter.)
4 rgHP Regular Hot Price rgHP is not available in dryer. (It can’t enter.)
5 dELC Dryer Moisture Sense dELC is not available in dryer. (It can’t enter.)
6 ItrC Interval Regular Cycles Number of Regular cycles ( 0~65535 )
7 ItCC Interval Regular Cold Cycles ItCC is not available in dryer. (It can’t enter.)
8 ItAC Interval Regular Warm Cycles ItAC is not available in dryer. (It can’t enter.)
9 ItHC Interval Regular Hot Cycles ItHC is not available in dryer. (It can’t enter.)
10 ItSC Interval Super Cycles ItSC is not available in dryer. (It can’t enter.)
11 IttF Interval Topo Cycles (Dryer Only) Number of Topo cycles ( 0~65535 )
12 ItUC Interval Service Cycles Number of Service cycles (0~65535)
13 ItFC Interval Token Cycles Number of Token cycles (0~65535)
14 ACrC Accumulated Regular Cycles Number of Regular cycles ( 0~65535 )
15 ACCC Accumulated Regular Cold Cycles ACCC is not available in dryer. (It can’t enter.)
16 ACAC Accumulated Regular Warm Cycles ACAC is not available in dryer. (It can’t enter.)
17 ACHC Accumulated Regular Hot Cycles ACHC is not available in dryer. (It can’t enter.)
18 ACSC Accumulated Super Cycles (Washer Only) ACSC is not available in dryer. (It can’t enter.)
19 ACtF Accumulated Topo Cycles (Dryer Only) Number of Topo cycles ( 0~65535 )
20 ACUC Accumulated Service Cycles Number of Service cycles ( 0~65535 )
21 ACFC Accumulated Token Cycles Number of Token cycles (0~65535)
22 ACrt Accumulated Run Time Number of Running minutes ( 0~65535)
MFL62512875_150414.indd 44 2015.4.14 9:44:8 AM