CHOOSE THE PROPER LOCATION
• Storeandinstallthedryerwhereitwillnotbe
exposed to temperatures below freezing or
exposed to outdoor weather conditions.
• Choosealocationwithasolid,leveloor.
• Ifthedryerisbeinginstalledinagarage,
place the dryer at least 18 in. (46 cm) above
the floor.
CLEARANCES
30"
(76.1 cm)
50"
(127 cm)
20"
(50.8 cm)
4"
(10 cm)
18"
(45.72 cm)
• Mostinstallationsrequireaminimum5½in.
(14 cm) clearance behind the dryer for the
exhaust ducting.
• Allowminimumclearancesofatleast1in.
(2.5 cm) on the sides and back to minimize
vibration and noise.
• Allowingadditionalclearanceforinstallationand
servicing is recommended.
• Besuretoallowforwall,door,oroormoldings
that may increase the required clearances.
• Allowatleast24in.(61cm)infrontofthedryer
to open the door.
IMPORTANT: Read all installation instructions completely before
installing and operating your dryer!
It is important that you review this entire manual before installing and using your dryer. Detailed instructions
concerning electrical connections, gas connections, and exhaust requirements are provided on the
following pages.
• Properlygrounddryertoconformwithall
governing codes and ordinances.
• Toreducetheriskofelectricshock,donot
install the dryer in damp or wet locations.
• Ifyouareinstallingyourdryerinamanufactured
or mobile home, please refer to the section
Special Requirements for Manufactured or
Mobile Homes.
Additional Instructions for closet installations:
• Theclosetdoormustallowforsufcientairow.
Refer to the diagram above for minimum vent
opening requirements. A louvered door is also
acceptable.
• Makesurethatthereisatleast18in.(46cm)of
clearance above the dryer.
27"
(68.6 cm)
1"
(2.54 cm)
1"
(2.54 cm)
24 in.
2
(155 cm
2
)
3"
(7.6 cm)
3"
(7.6 cm)
48 in.
2
(310 cm
2
)
Closet Door Vent
Requirements
10
MFL62512824_en_100528.indd 10 5/28/10 4:14:07 PM