Quick settings
Owner’s Manual 25
ENGLISH
NOTE
The device in this mode can heat the heating and DHW.
- The heating water will heat to the temperature set in the basic menu Heating, 1. Circuit, 2. Cir-
cuit, 3. Circuit, and 4. Circuit. In the case of a FP error the temperature of heating water will heat
up to the set temperature with the parameter AntiFreeze in the menu AddSourceOnly.
- The DHW will heat up to the temperature set with the parameter DHW in the menu Backup
source.
As soon as heating with the device will be made possible again, set the parameter to
AddSourceOnly NO.
3
In the menu Additional source choose
AddSourceOnly NO with the key and
press the key (ENTER).
4
* * appear along the chosen parameter. Use
the key to change the value of the
parameter to Only add. source YES. Only the
source will run.
To confirm the settings press key (ENTER).
5
For returning to the basic view press the key
(MENU) twice.
6
In the first row, after switching on the Backup
source, the main display will display the
information about the status of the device
Heating - AddSourceOnly -.
Delay OFF
Mode PARALLEL
Rise for 5.0°C
* AddSourceOnly NO*
Delay OFF
Mode PARALLEL
Rise for 5.0°C
>AddSourceOnly YES<
Heating - AddSourceOnly -
Heating ► 40 °C
Return 32.3°C
DHW 49.0°C
Delay OFF
Mode PARALLEL
Rise for 5.0°C
>AddSourceOnly NO<