Advanced settings
44 Air-to-Water Heat Pump
PV signal
The PV signal can be turned on in the menu mode with the parameter D8-PV. It allows factory and
user settings:
- The factory control setting enables the control of the temperature operating mode. This means that
in the case of the winter mode (heating) you can turn on cooling. The parameter is set to D8-PV
Cooling. It is most often used in combination with photovoltaic systems.
- The user control setting with parameters D8-PV Rise 1, 2, 3 ... enables the parameters listed below
to raise various operating modes and with it to change the temperature of the mode:
a) Rise 1: Comfort mode for the buffer tank.
b) Rise 2: Comfort mode for the DHW.
c) Rise 3: Comfort mode for the circuits.
d) Rise 4: Comfort mode for the buffer tank and circuits.
e) Rise 5: Comfort mode for the DHW and circuits.
f) Rise 6: Comfort mode for the buffer tank and DHW.
g) Rise 7: Comfort mode for the buffer tank, DHW and circuits.
Silent operation mode
Devices enable two additional operation modes set in the menu Mode with the parameter Silent
mode: The setting NRM switches the mode of operation into normal heating or cooling mode. The
setting LOW lowers the parameters of power and noise of the device in the heating or cooling mode.
The time and day of operation for these two parameters can be adjusted in a similar manner as the
schedule. The lowered frequency of operation of the device means that the compressor and ventila-
tors will operate with a lower power and consequently the operation of the device will be less noisy
and its power correspondingly smaller.
1
In the menu mode use the key to choose
the parameter Silent mode. When the symbols
> < appear next to the parameter Silent mode,
press the key (ENTER).
2
The day blinks which the schedule refers to.
Choose the day you would like to set the
schedule by using keys or .
When you choose the day press the key
(ENTER).
Temp. mode 12°C
H/T all 0°C
DI8
> Silent mode <
MON Copy DELETE
00:00 NRM --:-- NRM
--:-- NRM --:-- NRM
--:-- NRM --:-- NRM

Other manuals for LG THERMA V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG THERMA V and is the answer not in the manual?

LG THERMA V Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR32
Operating Temperature Range (Heating)-25°C to 35°C
Power Supply220-240V, 50Hz
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Noise Level (Indoor Unit)20 - 45 dB(A)
Noise Level (Outdoor Unit)45 - 60 dB(A)

Related product manuals