Rev: 03.02.2017
Page 13
Ground Control 3.0 with OneControl
OneControl Touch Panel Error Codes
NOTE: Faults can only be cleared via the OneControl Touch Panel or OneControl Leveling App through
MyRV®. The only exception is when the Auto Leveling Control Touch Panel (Fig. 1) was used to abort
an auto-sequence. In this case the fault can be cleared by pressing any Auto Leveling Control button.
Touch Panel
Message
What's Happening? What Should I Do?
"EXCESS ANGLE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
"EXCESSIVE ANGLE"
Controller not properly secured. Check and secure controller placement.
Excessive angle reached during
manual operation.
Relocate the coach.
"BAD CALIBRATION"
Trailer zero point was not set
correctly.
Reset zero point.
"FEATURE DISABLED"
Hitch recognition requested but no
hitch height set.
Perform "AUTO LEVEL" sequence to
establish hitch height.
Zero point not set. Set zero point.
"LOW VOLTAGE"
Bad connection or wiring.
Discharged or bad battery.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
"OUT OF STROKE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the trailer.
"EXTERNAL SENSOR" Bad connection or wiring.
Replace or repair connection to rear remote
sensor.
"JACK TIME OUT"
System could not level in expected
time.
Check disposition of jacks.
"AUTO LEVEL FAIL"
Unsecured controller.
Voltage drop.
Check and secure controller placement.
Test battery voltage under load - charge or
replace.
"FUNCTION ABORTED"
User has aborted an automatic
leveling sequence.
Hit OK. Restart the sequence.
"HALL POWER SHORT"
Short circuit detected on one or
more of the jack hall effect power
lines.
Check harness and replace or repair.
What Is Happening? Why?
Off Touch panel is locked.
Solid Green Touch panel is active.
Blinking Green Jacks are moving.
Solid Red Low battery.
Blinking Red
Error - Refer to OneControl Touch Panel screen or the Leveling App for the
specific error, then consult the Troubleshooting section of this manual to clear
the error.
Red/Green LED Indicator on Auto Leveling Control Touch Panel