15
Electrical Connection
Fitting Guidelines
The oven is manufactured to work with single-phase alternating
current (220V- 240V/50Hz). The connection diagram is also found on
the cover of the connection box.
Remember that the connection wire should match the connection
type and the power rating of the oven.
The connection cable must be secured in the strain-relief clamp.
Connection Diagram
For 220V ~ 240V earthed single-phase connection, links connect
terminals 1,2 and 3 and also 4 and 5. Do not remove these links
for use on single phase connections.
The brown wire must be connected to the Live terminal (L).
The blue wire must be connected to the Neutral terminal (N).
The Earth wire must be connected to the Earth terminal ( ).
NL
230V~ 3 × 1.5 mm
2
This appliance must be earthed.
For this connection a power lead with a minimum
specication 3 core × 1.5mm
2
type H05VV-F (PVC
insulated and sheathed) should be used.
• All electrical work should be carried out by a
competent person, if in doubt use a qualified
electrician.
• No alterations or changes in the electricity supply
should be carried out.
• This product must be earthed. The electrictity supply
for the oven must have an all pole disconnection
switch which enables the power to be cut off in case
of an emergency / maintenance. The distance between
the working contacts of the safety switch must be at
least 3 mm.
• Before connecting the oven to the mains power supply
it is important to read the information on the data
plate and the connection diagram.
• Voltage of heating elements 220V ~ 240V.
• This product must be Earthed.