For the installation of the supply cable carry out the following operations:
Release both clips then open the junction box lid.
Colours of the wires in the mains lead should correspond with
the markings identifying the terminals. Proceed as follows:
Green & Yellow wire to terminal marked E or
.
Brown wire to terminal marked L” .
Blue wire to terminal marked N” .
Ensure all screws are adequately tightened. Do not over tighten
as you may risk damaging the screw threads.
Fix the supply cable in the cable clamp and then close
the cover.
Electrical Connection
Electric cookers come without a power supply cable. The cooker is designed to operate on an electricity supply
which conforms to the electrical data shown on the Rating Plate. The cooker can be connected to the mains only
after you complete the connection at the junction box.
Live Earth
Neutral
HOTHOT
Junction
Box
The following installation procedure must be carried out by a competent person. If in doubt consult
a qualified electrician. The electrical installation must comply with the IEE Regulations, Building & local
By-Laws.
The power supply cable must have these minimum
requirements:
Type: H05VV-F (PVC insulated and sheathed
flexible cable)
Section: 3 core x 4 mm
2
This appliance must be earthed.
The cooker must be connected to the mains supply via a switch
providing full disconnection correctly fused with a capacity
appropriate to that shown on the cooker Rating Plate and
incorporated in the fixed wiring in accordance with the latest
wiring regulations. All electrical wiring from the consumer unit
to the cooker, via the full disconnection switch must be of the
correct rating.
The mains cable must be positioned away from any hot parts
at the rear of the cooker. If this cannot be done then another
method of protecting the mains cable from the hot parts must be
used i.e. Heat resistant sleeving or high temperature cables.
* All images are for indication only; please refer to your individual unit for actual item.
Logik Free Standing Electric Double Oven LDOC60W17 Manual.indd 25Logik Free Standing Electric Double Oven LDOC60W17 Manual.indd 25 14/01/2021 16:2114/01/2021 16:21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Logik LDOC60X17 and is the answer not in the manual?

Logik LDOC60X17 Specifications

General IconGeneral
BrandLogik
ModelLDOC60X17
CategoryOven
LanguageEnglish

Related product manuals