55
DATE
22.12.2003
COMPILER TECO/ATI
REG. CODE
1-5302-467
MODEL N°
50707
DATE OF ISSUE
06-95
REVISION 05
ENDORSED
108
111 112
109 110
X
15 LD
225-315-350
15 LD
315-350 EPA
400-440
2
1
3
FUEL SYSTEM
Injection pump non-return valve
The exhaust union has a non-return valve A. The purpose of this
valve is to improve the injection phase by expelling the air in the fuel
and preventing it from being sucked in by the pump during the
intake phase. This also ensures that the engine stops promptly as
soon as the stopping device is activated by means of the solenoid
valve.
Outlet fitting components for 315-350 EPA E 400-440 engines
1) Outlet fitting
2) Ball Ø1/8"
3) Threaded dowel
Do not cut the tube longitudinally because you might damage
the union.
Injection pump, Rilsan tube removal
Cut nylon tube at A.
Remove the portion of the tube which is still connected to the union
using common pliers. Pinch the nylon tube without impairing the
sealing properties of union (see figure).
Re-cycle the same feeding tube if the remaining length allows it;
replace if not.
Injection pump, Rilsan tube refitting
The outlet tube is made of nylon type Rilsan; it is connected to the
suitable injection pump union by means of special pliers (Ser.No.
7104-1460-023) and a plastic-head hammer (see figure).

Table of Contents

Other manuals for Lombardini 15 LD 225

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lombardini 15 LD 225 and is the answer not in the manual?

Lombardini 15 LD 225 Specifications

General IconGeneral
BrandLombardini
Model15 LD 225
CategoryEngine
LanguageEnglish

Related product manuals