EasyManuals Logo
Home>Lorentz>Water Pump>PS600 CS-F

Lorentz PS600 CS-F User Manual

Lorentz PS600 CS-F
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
8.4.4 Suction Head
The maximum suction head is limited by the local air pres-
sure, the water temperature of the medium, the pipe losses
and the NPSH value of the pump.
CAUTION – If the suction pressure in the
pump is lower than the vapor pressure of
the fluid, cavitation will occur. Cavitation
creates noise and will damage the pump.
Damage due to cavitation is not subject to
warranty. To avoid cavitation, the pressure
of the fluid must be maintained above its
vapor pressure at all points as it passes
through the pump.
The maximum suction head (H) must be calculated in
advance. The LORENTZ pump sizing software COMPASS can
be used for NPSH calculation.
46 Pump Installation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lorentz PS600 CS-F and is the answer not in the manual?

Lorentz PS600 CS-F Specifications

General IconGeneral
BrandLorentz
ModelPS600 CS-F
CategoryWater Pump
LanguageEnglish

Related product manuals