SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual Technology Switch with Occupancy Sensor
369773b 3 12.19.13
Maestro® Sensor
Custom Settings
Default settings shown in bold
- Timeout
• 30 min
• 15 min
• 5 min
• 1 min
Mode - Sensor Modes
Lights automatically turn off in all sensor modes
• Occ -Occupancy mode (No ALD)
1,2,3
• Lrn - Occupancy with learning ALD mode
• Fixd - Occupancy with fixed ALD mode
• Vac - Vacancy mode (No ALD)
2,3
1 MS-B102-XX default is Occ
2 MS-B102-V-XX is locked as Vac
3 MS-B202-XX defaults are: Circuit 1 - Occ, Circuit 2 - Vac
- Ultrasonic Sensitivity
• High
• Med
• Low
• Off
- Passive Infrared Sensitivity
• High
• Med
• Low
• Min
Additional Settings
Fixed ALD Light Level
• Hi
• Med
• Low *
• Min
*
“Low” is the default setting for any sensor that is
set by the user to: Occupancy with fixed ALD mode
Off-While-Occupied
• Enabled
• Disabled
Walk-Thru Mode
• Enabled
• Disabled
Custom Settings - Details
Ambient Light Detection (ALD) mode
Lights turn on only when natural light in the room is
below the set threshold.
– Learning: The Ambient light threshold adjusts to
the user’s preference via manual interaction with
the sensor switch.
– Fixed: Choose a fixed ALD light level from four
pre-set options:
High, Medium, Low, and Minimum
Manual Off-While-Occupied Options
ENABLED (default setting)
– When the sensor switch is manually turned off,
the sensor switch will not turn the lights back on
automatically while the room is occupied.
– Once the room is vacated, the Auto-on feature
returns to normal operation after the timeout
period has expired.
– This may be the preference in conference rooms
or classrooms while viewing presentations. This
feature requires motions to keep the lights off.
DISABLED
– When the sensor switch is manually turned off,
the Auto-on feature will return to normal operation
after 25 seconds.
– This may be the preference in a restroom if the
user always wants the lights to turn on upon
entering and the lights to turn off when the room
is vacant.
Walk-Thru Mode
ENABLED
1
–
If motion is not detected within 3 minutes after initial
occupancy, the lights will turn off after 3 minutes,
instead of the current timeout.
–
This setting may be the preference in commercial
applications where personnel may briefly trigger
sensors during non-working hours.
DISABLED
(default setting)
–
When motion is detected, the lights will ALWAYS remain
on for the entire timeout duration, regardless of the
duration of occupancy detection.
1
1 minute timeout would be overridden if walk-thru mode is
also ENABLED