Commissioning and operation
19
Operation monitoring system
Caution:
Do not overload the engine. Do not exceed the maximum permissible engine tilt.
If faults occur, find their cause immediately and have them eliminated in order to
prevent more serious damage!
During operation the oil pressure in the engine lubrication system must be monitored.
If the monitoring devices register a drop in the lube oil pressure, switch off the engine
immediately.
Shutting down
Do not switch off engine immediately operation at high loads, but let it idle for about
5 minutes to achieve a temperature equalisation.
Then switch off engine manually via the stop lever at the injection pump or via the stop
device provided (shutdown solenoid, electric speed governor etc.)
Danger:
Ensure that the engine can not be started by unauthorized persons.