Maintenance and Care
MAN-Industrial diesel engines D2842 LE103
55
Carefully read the Operating Instructions before starting any work!
This is especially valid for the chapter on General Safety Instructions
and the safety instructions in each of the chapters.
8.4.3 Fuel Filter - Drain Condensation
DANGER!
Fire hazard caused by uncontrolled fuel leakage
When opening the fuel system, fuel can leak out uncontrolled.
For this reason:
S Work carefully.
S Do not spill any fuel.
1. Open drain screw (1).
2. Drain condensation into a suitable container
until pure fuel flows out.
3. Tighten drain screw (1).