Maintenance and Care
MAN-Industrial diesel engines D2842 LE103
56
Carefully read the Operating Instructions before starting any work!
This is especially valid for the chapter on General Safety Instructions
and the safety instructions in each of the chapters.
8.4.4 Changing Fuel Filter Element
DANGER!
Fire hazard caused by uncontrolled fuel leakage
When opening the fuel system, fuel can leak out uncontrolled.
For this reason:
S Work carefully.
S Do not spill any fuel.
1 Close shutoff valves between engine and tank.
2. Open drain screw (4).
3. Drain fuel into suitable container.
4. Tighten drain screw (4).
5. Unscrew and remove filter cover (3) along with
O-ring (2).
6. Remove filter element (1).
7. Clean filter cover (3).
8. Insert new filter element (1) into housing.
7. Install new O-ring (2) onto filter cover (3).
8. Screw in and tighten filter cover (3).
Tightening torque 25 Nm.......................
The second filter element is changed in the same
way.
9. Bleed fuel system, see page 57.