Engine lubrication Force feed lubrication
Lubrication oil pressure during ope
ration (depends on engine speed,
oil temperature and engine load)
must be monitored via an oil pressure monitor or a display device
Oil filter Single-use main flow filter (easy-change filter)
Oil capacity in oil sump (litres) min. max.
half deep 17 l 25 l
Oil change quantity (with filter) 26 l
Engine cooling system Liquid cooling
Coolant temperature
Inlet temperature min. 80_C
Outlet temperature max. 88°C
Coolant filling capacity in engine approx. --
Electrical equipment
Starter 24 V; 4 KW
Test values
Natural gas operation Biogas operation
Lambda (oxygen) 1.62 1.42