Manitowoc Published 12-05-17, Control # 035-23 3-25
18000 SERIVCE/MAINTENANCE MANUAL ELECTRIC SYSTEM
96L NS-2 Node Select 2 Jumper to Ground 0 Volts (With Jumper)
96M NS-3 Node Select 3 Jumper to Ground 0 Volts (With Jumper)
96U Ground Jumper to Node Select 2 Ground
96W Ground Jumper to Node Select 3 Ground
MAX-ER Remote Controls
8SR/W51-A Power
8SR/W51-V Power
54LA/W51-B Left Front Jack - Extend
54LB/W51-C Left Front Jack - Retract
54RA/W51-D Right Front Jack - Extend
54RB/W51-E Right Front Jack - Retract
54LC/W51-F Left Rear Jack - Extend
54LD/W51-G Left Rear Jack - Retract
54RC/W51-H Right Rear Jack - Extend
54RD/W51-J Right Rear Jack - Retract
54AC/W51-KW All Jacks - Extend
54BD/W51-LX All Jacks - Retract
58RD/W51-M Right Steering Pins - Disengage
58RE/W51-N Right Steering Pins - Engage
58LD/W51-P Left Steering Pins - Disengage
58LE/W51-Q Left Steering Pins - Engage
59CC/W51-R Steering Position - Counterclockwise
59CW/W51-S Steering Position - Clockwise
89N3/W51-T Counterweight - Raise
89K3/W51-U Counterweight - Lower
1
ā Lower four bits are the most significant bit of the analog value.
Can ID. #
/Connector #
Function
Type
Description Test Voltage Packet No.