HOISTS 18000 SERIVCE/MAINTENANCE MANUAL
5-12
Published 12-05-17, Control # 035-23
Disconnecting Block-Up Limit Control
See Figure 5-9 for the following procedure.
Terminating plug (2, Views A and B) is provided so the block-
up limit control can be disconnected for the following
reasons:
⢠Crane setup and rigging
⢠Maintenance
If electric cable (3) is terminated, all of the block-up limits (on
boom and jib), the RCL, and the wind speed indicator will be
inactive.
FIGURE 5-9
Item Description
1 Sealing Cap (3 each)
2 Terminating Plug
3 Electric Cable WNE14
4 Electric Cable WBM150 from Cable Reel
5 Boom Node Controller *
6 Sealing Cap (14 each)
7 Terminating Plug (5 each)
8 Wind Speed
9 Digital Output
10 Block Level Switch 1 (Past Production)
11 Block Level Switch 2 (Past Production)
12 Electric Cable from Boom Cable Reel
13 Block-Up Limit (Lower Point ā Boom or Jib)
14 Block-Up Limit (Upper Point ā Boom or Jib)
15 Electric Cable Out to Jib
16 Luffing Jib Max Angle Limit
17 Luffing Jib Max Angle Limit
18 Luffing Jib Min Angle Limit
* An identical controller (less luffing jib angle
receptacles) is mounted on luffing jib point.